Conergy PowerPlus 210M–230M
|
|
![]() |
![]() |
Benets for the system operator:
Benets for the installer:
|
![]() |
| 1|Cell High performer: The highly-efficient 3 busbar cells indicate an optimised cell design and innovative technology. |
2|Frame and glass All-weather professional: Whether wind pressure, snow loads or temperature fluctuations – the 4 mm thick solar glass and warp resistant frame can withstand the most extreme of conditions. |
![]() |
| 3|Junction box Continuous operation: The waterproof junction box with 3 passively cooled bypass diodes guarantees maximum yields even in unfavourable environmental conditions. |
4|Inverter Easily combinable: Conergy PowerPlus modules are unbeatable in conjunction with Conergy inverters. |
![]() |
| 1According to the current warranty conditions of Conergy AG 2The warranty extension is an after sales product of the respective sales organisation in your country. |
||
![]() |
|
| Conergy PowerPlus 210M |
Conergy PowerPlus 215M |
Conergy PowerPlus 220M |
Conergy PowerPlus 225M |
Conergy PowerPlus 230M |
|
| Nominal power at STC³ | 210 Wp | 215 Wp | 220 Wp | 225 Wp | 230 Wp |
| Power tolerance | -0/+2.5% | -0/+2.5% | -0/+2.5% | -0/+2.5% | -0/+2.5% |
| Effi ciency of the module | 12.90 % | 13.21 | 13.51 % | 13.82 % | 14.13 % |
| Rated voltage (U ) | 28.49 V | 28.93 V | 29.37 V | 29.79 V | 30.14 V |
| Rated current (Impp) | 7.44 A | 7.50 A | 7.56 A | 7.62 A | 7.68 A |
| Open-circuit voltage (Uoc) | 34.44 V | 35.08 V | 35.73 V | 36.33 V | 37.03 V |
| Short-circuit current (Isc) | 8.14 A | 8.16 A | 8.18 A | 8.20 A | 8.22 A |
|
Temperature coeffi cient (Pmpp) procentual |
–0.45 %/°C | –0.45 %/°C | –0.45 %/°C | –0.45 %/°C | –0.45 %/°C |
| Temperature coeffi cient (Uoc) absolute |
–0.121 V/°C | –0.122 V/°C | –0.123 V/°C | –0.123 V/°C | –0.123 V/°C |
| Temperature coeffi cient (Uoc) procentual |
–0.34 %/°C | –0.34 %/°C | –0.34 %/°C | –0.34 %/°C | –0.34 %/°C |
| Temperature coeffi cient (Isc) absolute |
+4 mA/°C | +4 mA/°C | +4 mA/°C | +4 mA/°C | +4 mA/°C |
| Temperature coeffi cient (Isc) procentual |
+0.05 %/°C | +0.05 %/°C | +0.05 %/°C | +0.05 %/°C | +0.05 %/°C W |
| Warranted power 1 2 |
12/92 years/% | 12/92 years/% | 12/92 years/% | 12/92 years/% | 12/92 years/% |
| Warranted power 2 2 |
25/80 years/% | 25/80 years/% | 25/80 years/% | 25/80 years/% | 25/80 years/% |
1 Nominal operating temperature of the cell at 800 W/m² irradiation, 20° C ambient temperature, wind speed of 1 m/s
2 According to the current warranty conditions of Conergy AG. The warranty extension is an after sales product of the respective sales organisation in your country.
3Standard Test Conditions defi ned as follows: 1,000 W/m2 radiant power at a spectral density of AM 1.5 and a cell temperature of 25° C
4 According to IEC 61215 Ed. 2